ECOTECH MP40 MANUAL PDF

MP40 Data Sheet, application/pdf, MB, 08/06/ VorTech MP40w ES Propeller Pump Gen 2 MP40 Manual, application/pdf, MB, 10/27/ Your vortech propeller pump before you start, Adjust the pin spacer • Read online or download PDF • EcoTech Marine Gen 2 MP40 User Manual. MP40w ES. MP10 ES/ MP10w ES. For the full VorTech Pump manual, please visit our website at • Read this manual before installing .

Author: Gall Dotaur
Country: Bolivia
Language: English (Spanish)
Genre: Sex
Published (Last): 4 February 2005
Pages: 481
PDF File Size: 18.12 Mb
ePub File Size: 2.16 Mb
ISBN: 968-7-61219-620-2
Downloads: 18846
Price: Free* [*Free Regsitration Required]
Uploader: Voodoozshura

Powering Your EcoSmart Driv Pump Configuration for Ecotedh Modes. Use of this module in products not consented by EcoTech Marine is prohibited. If it fails again, contact EcoTech Marine Support for further assistance.

Documentation – EcoTech Marine

Specifications and Operating Parameters Flow: The parts store offers the most commonly ordered service parts 24 hours a day, seven days a week. This example would be the startup sequence for Firmware Revision 1. Assigning Local Max Speed To A Slave While normally you cannot change the speed of a slave pump, because the speed is determined entirely by the master pump, with the EcoSmart driver you now have the ability to control the maxi- mum speed of individual slave pumps independently from the master.

Assigning Local Max Speed t Page 37 Upgrade Completed Successfully: The VorTech pump is designed to operate with a constant gap between both halves of the device. Page 8 – Chapter 3: The dim LEDs showing the speed setting. Mp0 text from picture: The EcoTech Marine Battery Backup sold separately mamual with your VorTech pump is a unique accessory which greatly improves your likelihood of emerging from a power outage condition without any loss of livestock.

Comments to this Manuals Your Name. Page of 44 Go. Similarly to the MP40w, the MP10w comes with the EcoSmart Wireless Driver that enables wireless coordination and enhanced functionality between multiiple With all the electrical components outside the aquarium and a variety of easy-to-program modes, the VorTech is the saf- est, most versatile pump on the market.

  ESCLERODERMIA MORFEA PDF

Adjust the pin spacer.

Any water allowed into these components can damage them enough to require replacement. While normally you cannot change the speed of a slave pump, because the speed is determined entirely by the master pump, with the EcoSmart driver you now have the ability to control the maxi- mum speed of individual slave pumps independently from the master.

For more information on operating slave pumps and configuration, manuzl Chapter 5: Go into Feed Mode by holding the Mode button for three seconds. Maintenance Pump Disconnect Error Protection The VorTech pump can automatically shut itself down in the event that a motor and wetside de- couple from one-another.

It may then be cleaned of any obstructions. Specifications and Operating Parameters. This will come in handy if Pump Disconnect Error Prote Page 16 Slave pumps can only be set to sync or anti-sync modes, or the three options in EcoS- mart modes.

Wireless Driver Firmware Up Any wa- ter allowed into these components can damage them enough to require replacement. You may setup a maximum of seven separate groups, each having a unique master pump.

Table Of Contents Section 4. To remove the nozzle from the wet frame, remove the entire wet half of the pump from the aquarium and place it on a non-metallic surface. Other Modes Page 27 Page 28 – Section 4. Take care to place the VorTech in a suitable location where corals are not directly in the line of flow.

  AKTA ARKITEK 1967 PDF

EcoTech Marine shall not be held liable for damage to any aquarium, aquarium ectoech forms, or other personal objects due to improper use of the device. Troubleshooting Page 41 – Section 7. Because there are no other panes of glass to place additional pumps, slave pumps should not be run in the turquoise mode at all for an aquarium with this configuration.

Maintenance General Manintenance Cleaning fcotech VorTech The VorTech may need thorough cleaning of the components periodically to keep it running opti- mally. Pump Configuration for EcoSma Short Pulse Mode can then be used if you would like a wave running all the time, or you can use an EcoSmart mode which will auto-load your saved wave frequency and use it during points in the EcoSmart program.

Page 14 – Section 3. Once you have chosen the location where you wish to install your VorTech pump, clean away any algae, calcified or otherwise, using a razor blade. The EcoSmart Wireless Driver enables wireless coordination and en- hanced functionality between multiple MP40w ES units right out of the box, with no extra equipment to buy—making it the most effective solution on the market for larger aquariums.

Ecotech Marine EcoSmart User Manual

Advanced EcoSmart Pump Positioning To adjust for the proper aquarium thickness, pull the pin spacer from the motor housing. Other Modes This can result in death of your fish and coral inhabitants. Configuration Mode Chapter 5: The pin spacer is used to ensure the proper spacing for various aquarium wall manua.